Selectra E

1,200,000.00

  • Kinetic measurement with linearity check
  • Bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction
  • Two point measurement
  • Graphic plot of all measuring points
  • Automatic rerun with sample reduction
  • Non-linear calibration curves

Description

Throughout

  • Up to 180 tests per hour
  • Up to 300 tests per hour with ISE unit

Reagent System

  • Rotor with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. All positions can be assigned as R1, R2, R3. Adapters for 5 ml bottles in 25 ml positions
  • 5 pairs of 25 ml positions can be used for 50 ml bottles
  • Reagent 1 volume 110-400 µl
  • Reagent 2 volume 0-180 µl
  • Reagent 3 volume 0-180 µl
  • Reagent disk compartment is cooled to approx. 12° C below ambient temperature
  • Preheated reagent needle with level detection and integrated mixer

Sample System

  • Sample rotor containing
  •         Outer segment with 51 positions for samples and/or controls
  •         Inner segment for calibrators, controls, stats, blank and wash solution
  • Stat and pediatric functionality
  • Continuous loading
  • All positions can contain 5 ml primary tubes or sample cups
  • Sample volume 1-30 µl per test, programmable in steps of 0.1µl
  • Sample probe with level detection and intergrated mixer

Cuvette-Rotor

  • Semi-Disposable rotor with 48 cuvettes. Path length 7mm
  • > 10.000 tests per rotor
  • Min. measuring volume 220 µl
  • Measuring temperature 37° C, controlled by Peltier elements

Washing Unit

  • Cuvette-washing with 4 X 500 µl of water. The unit is equipped with liquid sensors. Waste is seperated into diluted and concentrated (sample/reagent mixture and optional ISE unit) waste. Cuvettes are dried before use

Light Source

  • Quarts-iodine lamp 12V-20W

Optics & Wavelength Range

  • Optical unit with an 8 position filter wheel
  • Automatic wavelength selection by 8-position filter wheel (340, 376, 405, 436, 505, 546, 578 and 620 nm)
  • Other wavelengths avaiable on request
  • Half bandwidth 8 to 12 nm

Photometric Range

  • -0.1 to 3.0 Absorbance

Analytical Modes

  • Kinetic measurement with linearity check
  • Bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction
  • Two point measurement
  • Graphic plot of all measuring points
  • Automatic rerun with sample reduction
  • Non-linear calibration curves